Electronic Miniature On-Delay
Timer
Miniature on-delay, plug-in timer.
Different models with a range of
settings between 0.1 sec and 6 hours
s
s
s
s
s
s
Four-pole changeover contacts rated at
3A @ 240VAC
AC and DC supply versions
Indications for time range, time up and
power on
Pin-out compatible with industry
standard, 4-pole plug-in relays
Sockets available for panel, surface, rail
or printed-circuit board mounting
Approved by standards:
UL (file no. E44592),
CSA (file no. LR60859)
TY4
Guarantee
Year
3
Options and ordering codes
T
Y
4
1
2
V
D
C
1
s
e
c
Timing range
1 sec
5 sec
Supply voltage
12VDC
24VDC
24VAC
110VAC
230-240VAC
10 sec
30 sec
60 sec
3 min
10 min
30 min
60 min
6 hour
PRODUCT
SPECIFICATION
OR
TO ORDER
Specifications
Timing range
1 sec
5 sec
10 sec
30 sec
60 sec
Time setting range
0.1 to 1 sec
0.4 to 5 sec
1 to 10 sec
2 to 30 sec
4 to 60 sec
Timing range
3 min
10 min
30 min
60 min
6 hour
Time setting range
0.25 to 3 min
1 to 10 min
2 to 30 min
4 to 60 min
0.5 to 6 hours
Repeat accuracy
Reset time
Max. switching frequency
Allowable ambient temperature
Mechanical life
Electrical life
Allowable operating voltage range
Contact ratings
Power consumption
Supply frequency AC types
Dielectric strength
Insulation Resistance
Vibration
Shock
卤0.1% at max. setting time
0.1 sec or less
1800 times/hour
-10藲C to +50藲C
50 million operations
800,000 operations at 1A 240VAC
0.85 to 1.1 times input voltage (230-240VAC type, 0.89 to 1.1 times input voltage range)
3A at 240VAC resistive load
1.9VA at 110VAC, 2.1VA at 240VAC, 1.1W at 24VDC
50/60Hz
2000VAC rms. 1 min. between current carrying part and non current carrying part
1500VAC rms. 1 min. between output contacts and control circuit
1000VAC rms. 1 min. between open contacts
100 M鈩?or more at 500VDC megger
Mechanical durability: 16.7Hz, 4mm double amplitude
Malfunction durability: 10 to 55Hz, 0.5mm double amplitude
Mechanical durability: 1000m/S
2
(Approx. 100G)
Malfunction durability: 50m/S
2
(Approx. 5G)