描述:1. Two-stage filters provide high performance in suppressing
both line-to-line and line-to-ground noise.
2. All part numbers are UL recognized, CSA certified and VDE
approved.
E
N
G
L
N
I
L
C1
L'
G'
N'
C2
Cy
Cy
L1
R
D
L2
C3
A
O
L
1. Maximum leakage current each
line-to-ground @ 115V AC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250V AC
6-7
GENERAL PURPOSE TWO-STAGE FILTERS
SERIES HIGH PERFORMANCE FILTERS
INTRODUCTIONS SPECIFICATIONS
COMPONENTS
R: 2.2M , Cy: 3300pF.
No safety approval yet, R: 1.0M
VDE approved to 16A/250VAC, C2: 0.33 uF
*
*
PART NO. C1,C2,C3(uF) L1,L2(mH)
02DRCG5
0.1 2.4
02DRCW5
03DRCG5
1.7
03DRCW5
03DRDG3S
2.8
03DRDW3S
05DRCG5
1.6 0.22
05DRCW5
05DRDG3S 1.3
1.3 05DRDW3S
10DRCG5
10DRCS5 1.0
10DRCW5
15DRCG5 0.1 0.9
20DRGG5
0.22 1.0
20DRGS5
ELECTRICAL SCHEMATIC
SERIES DIMENSIONS
PART NO.
AB C DE
3.25