TLE 6208-3 G
Fault Result Table
Fault
Overcurrent (load)
Short circuit to GND
(high-side-switch)
Short circuit to
V
S
(low-side-switch)
Temperature shut
down (SD)
Underload/Openload
Diag.-Bit
13
13
13
Result
Only the failed output is switched OFF. Function
can be deactivated by bit No. 13.
Only the failed output is switched OFF. Function
can be deactivated by bit No. 13.
Only the failed output is switched OFF. Function
can be deactivated by bit No. 13.
Reaction of control device needed.
All outputs OFF.
Temperature warning is set before.
Reaction of control device needed.
All outputs OFF.
All outputs OFF.
Function can be deactivated by bit No. 15.
Temperature warning 0
鈥?/div>
14
Undervoltage lockout 15
(UVLO)
Overvoltage lockout
(OVLO)
H = failure;
L = no failure.
15
Data Sheet
7
2001-05-10