鈮?/div>
3 ns
1.91V
Switching Characteristics
Over the Operating Range
-10
Parameter
t
S
t
A
t
CLK
t
CLKH
t
CLKL
t
DS
Description
Clock Cycle Frequency
Data Access Time
Clock Cycle Time
Clock HIGH Time
Clock LOW Time
Data Set-up Time
2
10
4.5
4.5
3
Min.
Max.
100
8
2
15
6
6
4
Min.
-15
Max.
66.7
10
2
25
10
10
6
Min.
-25
Max.
40
15
Unit
MHz
ns
ns
ns
ns
ns
Notes:
5. See the last page of this specification for Group A subgroup testing information.
6. Test no more than one output at a time for not more than one second.
7. Outputs open. Tested at Frequency = 20 MHz.
8. All inputs = V
CC
鈥?0.2V, except WCLK and RCLK, which are switching at 20 MHz.
9. Tested initially and after any design or process changes that may affect these parameters.
10. C
L
= 30 pF for all AC parameters except for t
OHZ
.
11. C
L
= 5 pF for t
OHZ
.
Document #: 38-06016 Rev. *A