TM
MP2354 鈥?2A, 23V, 380KHz STEP-DOWN CONVERTER
External Bootstrap Diode
It is recommended that an external bootstrap
diode be added when the system has a 5V
fixed input or the power supply generates a 5V
output. This helps improve the efficiency of the
regulator. The bootstrap diode can be a low
cost one such as IN4148 or BAT54.
5V
BS
MP2354
SW
10nF
MP2354_F03
Figure 3鈥擡xternal Bootstrap Diode
This diode is also recommended for high duty
cycle operation (when
V
OUT
>65%) and high
V
IN
output voltage (V
OUT
>12V) applications.
PACKAGE INFORMATION
SOIC8
PIN 1 IDENT.
0.229(5.820)
0.244(6.200)
0.150(3.810)
0.157(4.000)
0.0075(0.191)
0.0098(0.249)
SEE DETAIL "A"
0.013(0.330)
0.020(0.508)
0.050(1.270)BSC
0.011(0.280) x 45
o
0.020(0.508)
0.189(4.800)
0.197(5.004)
0.053(1.350)
0.068(1.730)
0.049(1.250)
0.060(1.524)
0
o
-8
o
0.016(0.410)
0.050(1.270)
DETAIL "A"
SEATING PLANE
0.001(0.030)
0.004(0.101)
NOTE:
1) Control dimension is in inches. Dimension in bracket is millimeters.
NOTICE:
The information in this document is subject to change without notice. Please contact MPS for current specifications.
Users should warrant and guarantee that third party Intellectual Property rights are not infringed upon when integrating MPS
products into any application. MPS will not assume any legal responsibility for any said applications.
MP2354 Rev. 1.4
1/6/2006
www.MonolithicPower.com
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited.
漏 2006 MPS. All Rights Reserved.