Pin numbers shown are for the D, DB, DGV, J, N, PW, and W packages.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
鈥?/div>
Supply voltage range, V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 鈥?.5 V to 7 V
Input voltage range, V
I
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 鈥?.5 V to 7 V
Output voltage range, V
O
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 鈥?.5 V to V
CC
+ 0.5 V
Input clamp current, I
IK
(V
I
< 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 鈥?0 mA
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
卤20
mA
Continuous output current, I
O
(V
O
= 0 to V
CC
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
卤25
mA
Continuous current through V
CC
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
卤75
mA
Package thermal impedance,
胃
JA
(see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73掳C/W
DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82掳C/W
DGV package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120掳C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67掳C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108掳C/W
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 鈥?5掳C to 150掳C
鈥?Stresses beyond those listed under 鈥渁bsolute maximum ratings鈥?may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under 鈥渞ecommended operating conditions鈥?is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.