Operation description
5
5.1
Operation description
Current mode topology:
The current mode control method, like the one integrated in the devices, uses two control loops
- an inner current control loop and an outer loop for voltage control. When the Power MOSFET
output transistor is on, the inductor current (primary side of the transformer) is monitored with a
SenseFET technique and converted into a voltage V
S
proportional to this current. When V
S
reaches V
COMP
(the amplified output voltage error) the power switch is switched off. Thus, the
outer voltage control loop defines the level at which the inner loop regulates peak current
through the power switch and the primary winding of the transformer.
Excellent open loop D.C. and dynamic line regulation is ensured due to the inherent input
voltage feedforward characteristic of the current mode control. This results in improved line
regulation, instantaneous correction to line changes, and better stability for the voltage
regulation loop.
Current mode topology also ensures good limitation in case there is a short circuit. During the
first phase the output current increases slowly following the dynamic of the regulation loop.
Then it reaches the maximum limitation current internally set and finally stops because the
power supply on V
DD
is no longer correct. For specific applications the maximum peak current
internally set can be overridden by externally limiting the voltage excursion on the COMP pin.
An integrated blanking filter inhibits the PWM comparator output for a short time after the
integrated Power MOSFET is switched on. This function prevents anomalous or premature
termination of the switching pulse in case there are current spikes caused by primary side
capacitance or secondary side rectifier reverse recovery time.
5.2
Stand-by mode
Stand-by operation in nearly open load conditions automatically leads to a burst mode
operation allowing voltage regulation on the secondary side. The transition from normal
operation to burst mode operation happens for a power P
STBY
given by :
Where:
1
2
F
-
P
STBY
= --
L
P
I STBY SW
2
L
P
is the primary inductance of the transformer. F
SW
is the normal switching frequency.
I
STBY
is the minimum controllable current, corresponding to the minimum on time that the
device is able to provide in normal operation. This current can be computed as :
(
t
b
+
t
d
)V
IN
I
STBY
= -----------------------------
L
p
t
b
+ t
d
is the sum of the blanking time and of the propagation time of the internal current sense
and comparator, and represents roughly the minimum on time of the device. Note: that P
STBY
may be affected by the efficiency of the converter at low load, and must include the power
drawn on the primary auxiliary voltage.
11/34

VIPER20A-E 产品属性

  • VIPER20A-E View All Specifications

  • VIPerPlus

  • 1,000

  • 集成电路 (IC)

  • PMIC - AC-DC 转换器,离线开关

  • VIPER™

  • 隔离

  • 90kHz ~ 200kHz

  • 8 V ~ 15 V

  • 700V

  • 57W

  • 25°C ~ 125°C

  • Pentawatt-5 HV(弯曲和错列引线)

  • 5-PENTAWATT

  • 管件

  • 497-6796-5VIPER20A-E-ND

VIPER20A-E相关型号PDF文件下载

您可能感兴趣的PDF文件资料

热门IC型号推荐

扫码下载APP,
一键连接广大的电子世界。

在线人工客服

买家服务:
卖家服务:

0571-85317607

客服在线时间周一至周五
9:00-17:30

关注官方微信号,
第一时间获取资讯。

建议反馈
返回顶部

建议反馈

联系人:

联系方式:

按住滑块,拖拽到最右边
>>
感谢您向阿库提出的宝贵意见,您的参与是维库提升服务的动力!意见一经采纳,将有感恩红包奉上哦!