ATmega8内部RC振荡器漂移测试
出处:awey 发布于:2007-04-29 10:03:59
27℃ Mean:141.313 Min:141.2439 Max:141.4173 Current:141.0/141.2
35℃ Mean:141.245 Min:141.0358 Max:141.4173 Current:140.9/141.0
40℃ Mean:141.18 Min:140.8892 Max:141.4173 Current:140.8/140.9
45℃ Mean:141.07 Min:140.7420 Max:141.4173 Current:140.7/140.8
50℃ Mean:141.03 Min:140.6983 Max:141.4173 Current:140.7/140.8
55℃ Mean:141.00 Min:140.6458 Max:141.4173 Current:140.6/140.7
60℃ Mean:140.97 Min:140.5294 Max:141.4173 Current:140.5/140.6
65℃ Mean:140.94 Min:140.4558 Max:141.4173 Current:140.4/140.5
70℃ Mean:140.91 Min:140.3302 Max:141.4173 Current:140.3/140.4
75℃ Mean:140.88 Min:140.2379 Max:141.4173 Current:140.2/140.3
80℃ Mean:140.84 Min:140.0747 Max:141.4173 Current:140.1/140.2
85℃ Mean:140.82 Min:139.9755 Max:141.4173 Current:140.0
90℃ Mean:140.76 Min:139.8568 Max:141.4173 Current:139.8
总结:
Mean是整个测量范围的平均值,只能作为参考,不能作为评估;Min是整个测量范围的值,可以作为参考,也可以作为评估(频率漂移和温度成线性关系);Max是整个测量范围的值,由于随温度升高频率降低,所以该值几乎没有意义;Current是当前测量值可以作为参考,也可以作为评估。
从上面的数据可以看出,随着温度的升高,RC振荡器呈现出随温度升高而降低的趋势,但是变化不是很明显,从Min的测量值进行频率的漂移计算可以得出:(141.2439-139.9755)/141.2439=0.89%;从Current的测量值进行频率的漂移计算可以得出:(141.2-139.8)/141.2=0.85%,基本可以认为从27℃到85℃的温度范围内内部RC震荡器的频率变化了0.8-0.9左右,对于UART而言,这样的变化导致的误码率还是有限的。
频率是个比较难测量的值,以上的Mean和Current数据都只取了比较稳定的几位,但是大致的频率趋势还是很明显的。
感谢NSC美国国家半导体提供LM2825 DC-DC模块,感谢浙江立德提供网站空间,感谢浙江立德提供测试设备!
版权与免责声明
凡本网注明“出处:维库电子市场网”的所有作品,版权均属于维库电子市场网,转载请必须注明维库电子市场网,https://www.dzsc.com,违反者本网将追究相关法律责任。
本网转载并注明自其它出处的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品出处,并自负版权等法律责任。
如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。
- 常见的激光雷达slam算法有哪些?2024/4/30 17:24:16
- 什么叫特高压电网2024/4/30 17:21:31
- 分布式光伏发电有什么优劣势2024/4/29 17:17:39
- 如何更好的理解lwip协议?2024/4/28 17:20:13
- 802.11ac连接的推荐设置_802.11AC无线网桥的配置和注意事项2024/4/28 17:10:43