鈥?/div>
Modify TPID to 0x810 + 鈥減ort mask,鈥?which indicates source port
No change to TCI, if VID is not null
Replace null VID with ingress port VID
Recalculate CRC
Not tagged
鈥?Insert TPID to 0x810 + 鈥減ort mask,鈥?which indicates source port
鈥?Insert TCI with ingress port VID
鈥?Recalculate CRC
Table 6. STPID Egress Rules (Switch to Processor)
IGMP Support
There are two parts involved to support IGMP in layer 2. The first part is 鈥淚GMP鈥?snooping. The switch will trap IGMP packets
and forward them only to the processor port. The IGMP packets are identified as IP packets (either Ethernet IP packets or IEEE
802.3 SNAP IP packets) AND IP version = 0x4 AND protocol number = 0x2. The second part is 鈥渕ulticast address insertion鈥?/div>
in the static MAC table. Once the multicast address is programmed in the static MAC table, the multicast session will be trimmed
to the subscribed ports, instead of broadcasting to all ports. To enable this feature, set register 5 bit 6 to 1. Also 鈥渟pecial tag
mode鈥?needs to be enabled, so that the processor knows which port the IGMP packet was received on. Enable 鈥渟pecial tag
mode鈥?by setting both register 11 bit 0 and register 80-bit 2.