TMS320F2810, TMS320F2812
DIGITAL SIGNAL PROCESSORS
SPRS174B 鈥?APRIL 2001 鈥?REVISED SEPTEMBER 2001
timing registers (continued)
The minimum timing settings for an XINTF access is as follows:
D
When the XREADY option is NOT used:
The minimum strobe setting is Lead = 1, Active = 0, Trail = 0
Hence: L = 0, A = 0,T = 0 settings are not allowed (L = 1, A = 0,T = 0 or L = 1, A = 1,T = 0 or L = 1, A = 0, T = 1 or
greater are allowed)
D
When the XREADY option is used:
The minimum strobe setting is Lead = 1, Active = 1, Trail = 0
Hence: L = 0, A = 0, T = 0 settings are not allowed (L = 1, A = 1, T = 0 or L = 1, A = 1, T = 1 or greater are
allowed).
No logic is included to detect illegal settings.